Crystal Quest Whole House Radium & Uranium Removal Water Filter | 1.5–2.0 Cu. Ft.
Choose options
Crystal Quest Whole House Radium & Uranium Removal Water Filter | 1.5–2.0 Cu. Ft.
Specialized Water Filtration for Radioactive Contaminants in Groundwater
Overview
Protect your household water supply with the Crystal Quest Whole House Radium & Uranium Removal Water Filter, designed to target naturally occurring radioactive contaminants found in certain groundwater sources.
Radium and uranium can enter drinking water through bedrock, soil, mining activity, and industrial contamination. Because these contaminants cannot be detected by taste, smell, or appearance, laboratory water testing is essential.
Available in 1.5 and 2.0 cubic foot configurations, this system features automatic backwashing, stainless steel or fiberglass tank options, and customizable treatment upgrades.
Ideal for private wells, rural properties, homesteads, and residential water systems with documented radium or uranium contamination.
Key Features & Benefits
-
Targeted Contaminant Reduction: Designed for water treatment applications involving radium and uranium.
-
Whole-House Installation: Treats water entering the property's main supply line.
-
Automatic Backwashing: Helps maintain filtration system operation.
-
Two System Capacities: Available in 1.5 and 2.0 cubic foot configurations.
-
9–13 GPM Service Flow: Supports residential water demands.
-
Tank Material Options: Stainless steel or fiberglass.
-
Customizable Treatment: Optional UV disinfection, leak protection, metered controls, and oxidation.
-
Specialist-Guided Configuration: Dosing and regeneration requirements are determined by incoming water chemistry.
The manufacturer's uranium-specific removal performance and media compatibility should be verified before purchase.
Understanding Radium & Uranium in Drinking Water
Radium
Radium is a naturally occurring radioactive element that can dissolve into groundwater as water passes through certain rock formations.
Long-term exposure to elevated radium concentrations can increase cancer risk.
Uranium
Uranium can enter groundwater through natural mineral deposits, mining activity, and industrial sources.
Long-term exposure may present kidney-related health risks, in addition to concerns associated with radioactivity.
EPA Drinking Water Limits
| Contaminant | EPA Maximum Contaminant Level |
|---|---|
| Combined Radium-226 & Radium-228 | 5 pCi/L |
| Uranium | 30 µg/L (0.030 mg/L) |
These are U.S. EPA drinking water standards for public water systems and useful reference values when evaluating private well water.
Important: Laboratory testing is necessary to determine whether treatment is required and to verify that treated water meets applicable safety standards.
How the System Works
Specialized Contaminant Removal
Water passes through a treatment media tank designed for radioactive contaminant reduction.
Media selection, treatment capacity, and regeneration requirements must be matched to the contaminants identified through water testing.
Automatic Backwashing
The system includes automatic backwashing to support filtration operation.
A timer-controlled valve is standard, with an optional metered valve that operates according to water usage.
Dosing & Regeneration
Consult a product specialist to determine whether chemical dosing or regeneration is required for your specific water conditions.
The appropriate treatment process depends on incoming water chemistry, contaminant concentrations, and the selected media.
Available Models & Specifications
| Specification | 1.5 Cu. Ft. | 2.0 Cu. Ft. |
|---|---|---|
| Filter Media Volume | 1.5 Cubic Feet | 2.0 Cubic Feet |
| Manufacturer-Listed Capacity | 1,000,000 Gallons | 1,500,000 Gallons |
| Service Flow Rate | 9–11 GPM | 10–13 GPM |
| Tank Dimensions | 10" × 54" | 12" × 52" |
| Tank Material | Stainless Steel or Fiberglass | Stainless Steel or Fiberglass |
| Backwash | Automatic | Automatic |
| Optional Softener Brine Tank | 18" × 33" | 18" × 33" |
| Optional Softener Grain Capacity | 48,000 Grains | 60,000 Grains |
Brine tank dimensions and grain capacities apply only when the optional water softener is selected.
Capacity Note: The manufacturer-listed gallon capacities do not establish guaranteed radium or uranium removal performance or media life. Actual treatment capacity must be determined from contaminant concentrations, water chemistry, and validated media performance.
Optional Water Treatment Upgrades
12 GPM UV Water Sterilizer
Adds ultraviolet disinfection for appropriately pretreated water.
UV treatment targets susceptible microorganisms but does not remove dissolved radium or uranium.
Leak Detector Valve
Detects water leaks and shuts off the water supply to help minimize flooding.
Vacuum Breaker
Helps protect filtration tanks and housings against negative pressure in the water line.
Metered Control Valve
Allows backwashing to be initiated based on water usage rather than a fixed schedule.
Oxidation System
Optional ozone-based oxidation treatment for compatible water quality applications.
Oxidation should not be assumed to remove radioactive contaminants without a validated treatment process.
Stainless Steel vs. Fiberglass Tanks
Stainless Steel
Suitable for installations where stainless steel construction is preferred and environmental conditions are compatible.
Fiberglass
Recommended by the manufacturer for environments exposed to high humidity, salt, or persistent condensation.
Stainless steel tanks may develop rust or pinholes under certain environmental conditions.
Ideal Applications
-
Private Well Water Treatment
-
Radium-Contaminated Groundwater
-
Uranium-Contaminated Groundwater
-
Rural Homes & Homesteads
-
Off-Grid Residential Properties
-
Properties Near Natural Mineral Deposits
-
Groundwater Treatment Infrastructure
-
Remote Residential Developments
Installation & Maintenance
Installation Requirements
-
Obtain laboratory testing for radium, uranium, and relevant water chemistry.
-
Confirm treatment media compatibility and documented removal performance.
-
Select the appropriate configuration based on household water demand.
-
Provide suitable plumbing, drainage, and electrical connections.
-
Determine whether dosing or regeneration is necessary.
-
Establish a treated-water testing and maintenance schedule.
Routine Maintenance
-
Monitor automatic backwashing and treatment performance.
-
Follow manufacturer requirements for media servicing and replacement.
-
Conduct periodic laboratory testing of treated water.
-
Maintain optional treatment components according to manufacturer instructions.
Radioactive Media Disposal: Treatment media and regeneration waste may concentrate radioactive contaminants. Disposal must follow applicable regulations and local requirements.
Warranty
Manufacturer warranty coverage, duration, and exclusions should be confirmed before purchase.
The OGH Difference
At Off-Grid Habitats, we provide specialized water treatment systems and essential infrastructure for residential, commercial, and off-grid developments.
We help customers identify appropriate equipment based on documented water quality, treatment requirements, and long-term maintenance considerations.
Address Radioactive Contaminants in Your Water Supply
Explore the Crystal Quest Whole House Radium & Uranium Removal Water Filter, available in 1.5 and 2.0 cubic foot configurations.
Request Your Personalized Quote Today to review laboratory water results, confirm treatment compatibility, and determine system sizing, configuration, pricing, and delivery.
Important: Do not rely on this system for drinking-water safety until the manufacturer confirms its suitability for the specific contaminants and independent testing verifies treated-water quality. No independent radium or uranium reduction certification was provided in the product information.